Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Sci Rep ; 13(1): 4941, 2023 03 27.
Article in English | MEDLINE | ID: covidwho-2265371

ABSTRACT

Despite Japan's high vaccination coverage, daily numbers of new COVID-19 cases have been high. However, studies on the seroprevalence among Japanese people and the causative factors for rapid spread have remained limited. In this study, we aimed to examine the seroprevalence and associated factors in healthcare workers (HCWs) of a medical center in Tokyo using blood samples drawn at annual check-ups from 2020 to 2022. We found that of the 3,788 HCWs in 2022 (by mid-June), 669 were seropositive for N-specific antibodies (tested by Roche Elecsys Anti-SARS-CoV-2 assay); the seroprevalence surged from 0.3% in 2020 and 1.6% in 2021 to 17.7% in 2022. Notably, our study found 325 (48.6%; 325/669) cases were infected without awareness. Among those with a previously PCR-confirmed SARS-CoV-2 infection during the past three years, 79.0% (282/357) were found after January 2022, after the Omicron variant was first detected in Tokyo at the end of 2021. This study indicates the fast spread of the SARS-CoV-2 among HCWs during the Omicron surge in Japan. The high percentage of infection without awareness may be a key driving factor causing rapid person-to-person transmission, as shown in this medical center with high vaccination coverage and strict infection control measures.


Subject(s)
COVID-19 , Health Personnel , Humans , Antibodies, Viral , COVID-19/epidemiology , East Asian People , SARS-CoV-2 , Seroepidemiologic Studies
2.
PLoS One ; 18(1): e0279779, 2023.
Article in English | MEDLINE | ID: covidwho-2214791

ABSTRACT

BACKGROUND: Despite the worldwide campaigns of COVID-19 vaccinations, the pandemic is still a major medical and social problem. The Ortho VITROS SARS-CoV-2 spike-specific quantitative IgG (VITROS S-IgG) assay has been developed to assess neutralizing antibody (NT antibody) against SARS-CoV-2 spike (S) antibodies. However, it has not been evaluated in Japan, where the total cases and death toll are lower than the rest of the world. METHODS: The clinical performance of VITROS S-IgG was evaluated by comparing with the NT antibody levels measured by the surrogate virus neutralizing antibody test (sVNT). A total of 332 serum samples from 188 individuals were used. Of these, 219 samples were from 75 COVID-19 patients: 96 samples from 20 severe/critical cases (Group S), and 123 samples from 55 mild/moderate cases (Group M). The remaining 113 samples were from 113 healthcare workers who had received 2 doses of the BNT162b2 vaccine. RESULTS: VITROS S-IgG showed good correlation with the cPass sVNT assay (Spearman rho = 0.91). Both VITROS S-IgG and cPass sVNT showed significantly higher plateau levels of antibodies in Group S compared to Group M. Regarding the humoral immune responses after BNT162b2 vaccination, individuals who were negative for SARS-CoV-2 nucleocapsid (N)-specific antibodies had statistically lower titers of both S-IgG and sVNT compared to individuals with a history of COVID-19 and individuals who were positive for N-specific antibodies without history of COVID-19. In individuals who were positive for N-specific antibodies, S-IgG and sVNT titers were similar to individuals with a history of COVID-19. CONCLUSIONS: Although the automated quantitative immunoassay VITROS S-IgG showed a reasonable correlation with sVNT antibodies, there is some discrepancy between Vitros S-IgG and cPass sVNT in milder cases. Thus, VITROS S-IgG can be a useful diagnostic tool in assessing the immune responses to vaccination and herd immunity. However, careful analysis is necessary to interpret the results.


Subject(s)
Blood Group Antigens , COVID-19 , Humans , BNT162 Vaccine , SARS-CoV-2 , Antibodies, Blocking , Antibodies, Viral , Immunoglobulin G , Antibodies, Neutralizing , COVID-19 Testing
3.
PLoS One ; 17(9): e0274181, 2022.
Article in English | MEDLINE | ID: covidwho-2140508

ABSTRACT

Quantitative measurement of SARS-CoV-2 neutralizing antibodies is highly expected to evaluate immune status, vaccine response, and antiviral therapy. The Elecsys® Anti-SARS-CoV-2 S (Elecsys® anti-S) was developed to measure anti-SARS-CoV-2 S proteins. We sought to investigate whether Elecsys® anti-S can be used to predict neutralizing activities in patients' serums using an authentic virus neutralization assay. One hundred forty-six serum samples were obtained from 59 patients with COVID-19 at multiple time points. Of the 59 patients, 44 cases were included in Group M (mild 23, moderate 21) and produced 84 samples (mild 35, moderate 49), while 15 cases were included in Group S (severe 11, critical 4) and produced 62 samples (severe 43, critical 19). The neutralization assay detected 73% positive cases, and Elecsys® anti-S and Elecsys® Anti-SARS-CoV-2 (Elecsys® anti-N) showed 72% and 66% positive cases, respectively. A linear correlation between the Elecsys® anti-S assay and the neutralization assay were highly correlated (r = 0.7253, r2 = 0.5261) than a linear correlation between the Elecsys® anti-N and neutralization assay (r = 0.5824, r2 = 0.3392). The levels of Elecsys® anti-S antibody and neutralizing activities were significantly higher in Group S than in Group M after 6 weeks from onset of symptoms (p < 0.05). Conversely, the levels of Elecsys® anti-N were comparable in both groups. Three immunosuppressed patients, including cancer patients, showed low levels of anti-S and anti-N antibodies and neutralizing activities throughout the measurement period, indicating the need for careful follow-up. Our data indicate that Elecsys® anti-S can predict the neutralization antibodies in COVID-19.


Subject(s)
Antibodies, Neutralizing , COVID-19 , Antibodies, Viral , Antiviral Agents , COVID-19/diagnosis , Humans , Immunoassay , Neutralization Tests , SARS-CoV-2
4.
Sci Rep ; 12(1): 14909, 2022 Sep 01.
Article in English | MEDLINE | ID: covidwho-2008319

ABSTRACT

COVID-19 antibody testing has been developed to investigate humoral immune response in SARS-CoV-2 infection. To assess the serological dynamics and neutralizing potency following SARS-CoV-2 infection, we investigated the neutralizing (NT) antibody, anti-spike, and anti-nucleocapsid antibodies responses using a total of 168 samples obtained from 68 SARS-CoV-2 infected patients. Antibodies were measured using an authentic virus neutralization assay, the high-throughput laboratory measurements of the Abbott Alinity quantitative anti-spike receptor-binding domain IgG (S-IgG), semiquantitative anti-spike IgM (S-IgM), and anti-nucleocapsid IgG (N-IgG) assays. The quantitative measurement of S-IgG antibodies was well correlated with the neutralizing activity detected by the neutralization assay (r = 0.8943, p < 0.0001). However, the kinetics of the SARS-CoV-2 NT antibody in severe cases were slower than that of anti-S and anti-N specific antibodies. These findings indicate a limitation of using the S-IgG antibody titer, detected by the chemiluminescent immunoassay, as a direct quantitative marker of neutralizing activity capacity. Antibody testing should be carefully interpreted when utilized as a marker for serological responses to facilitate diagnostic, therapeutic, and prophylactic interventions.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19 Testing , Humans , Immunoglobulin G , Immunoglobulin M , Sensitivity and Specificity
5.
Sci Rep ; 12(1): 8707, 2022 05 24.
Article in English | MEDLINE | ID: covidwho-1860401

ABSTRACT

In 2020, we reported a low seroprevalence of N-specific antibodies in 4147 health care workers (HCWs) at a frontline hospital in Tokyo, Japan. In Japan, a vaccine campaign was launched in early 2021. We re-evaluated seroprevalences of N- and S-specific antibodies in 2202 HCWs who took two doses of the BNT162b2 vaccine. In 2021, N-specific seroprevalence remains as low as 1.59%. The seroprevalences were comparable among all HCWs regardless of exposure levels. Almost all of the HCWs elicited S-specific antibodies after vaccination. However, the HCWs who had COVID-19 elicited higher S-specific antibody titers than those who did not have COVID-19. In the HCWs without a history of COVID-19, 1.1% (23 out of 2185) were seropositive with N-specific antibodies, indicating the existence of asymptomatic infections. Also, S-specific antibody titers were higher in females and younger HCWs, and in those who had severe side effects. However, S-specific antibody titers were lower depending on the number of days after the second dose of vaccination specifically in elderly individuals. In conclusion, this study indicates N-specific seroprevalence remains low in HCWs at a frontline hospital in Tokyo. The mRNA vaccine elicited S-specific antibody in HCWs, however, the titers decreased as the days proceeded.


Subject(s)
COVID-19 , Aged , Antibodies, Viral , Antibody Formation , BNT162 Vaccine , COVID-19/epidemiology , COVID-19/prevention & control , Female , Health Personnel , Hospitals, University , Humans , SARS-CoV-2 , Seroepidemiologic Studies , Tokyo/epidemiology , Vaccination , Vaccines, Synthetic , mRNA Vaccines
6.
J Virol Methods ; 302: 114477, 2022 04.
Article in English | MEDLINE | ID: covidwho-1654880

ABSTRACT

An immunochromatographic kit was developed to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses (A and B) on two detection positions of a single strip. The sensitivity and specificity for SARS-CoV-2 were 97.4 % and 100 %, respectively, and those for influenza viruses were 100 %, respectively.


Subject(s)
COVID-19 , Influenza A virus , Influenza, Human , COVID-19/diagnosis , Humans , Influenza B virus , Influenza, Human/diagnosis , SARS-CoV-2 , Sensitivity and Specificity
8.
Sci Rep ; 11(1): 23196, 2021 12 01.
Article in English | MEDLINE | ID: covidwho-1545648

ABSTRACT

Here, we aimed to evaluate the clinical performance of a novel automated immunoassay HISCL SARS-CoV-2 Antigen assay kit designed to detect the nucleocapsid (N) protein of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This kit comprises automated chemiluminescence detection systems. Western blot analysis confirmed that anti-SARS-CoV antibodies detected SARS-CoV-2N proteins. The best cut-off index was determined, and clinical performance was tested using 115 serum samples obtained from 46 patients with coronavirus disease 2019 (COVID-19) and 69 individuals who tested negative for COVID-19 through reverse transcription quantitative polymerase chain reaction (RT-qPCR). The HISCL Antigen assay kit showed a sensitivity of 95.4% and 16.6% in samples with copy numbers > 100 and < 99, respectively. The kit did not cross-react with human coronaviruses causing seasonal common cold and influenza, and none of the 69 individuals without COVID-19 were diagnosed with positive results. Importantly, 81.8% of the samples with low virus load (< 50 copy numbers) were diagnosed as negative. Thus, using HISCL antigen assay kits may reduce overdiagnosis compared with RT-qPCR tests. The rapid and high-throughput HISCL SARS-CoV-2 Antigen assay kit developed here proved suitable for screening infectious COVID-19 and may help control the pandemic.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/immunology , Immunoassay/methods , SARS-CoV-2/immunology , Blotting, Western , COVID-19/immunology , COVID-19/virology , Cross Reactions , Humans , Phosphoproteins/immunology
9.
Int J Lab Hematol ; 43(6): 1309-1318, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1409690

ABSTRACT

INTRODUCTION: Developing prognostic markers can be useful for clinical decision-making. Peripheral blood (PB) examination is simple and basic that can be performed in any facility. We aimed to investigate whether PB examination can predict prognosis in coronavirus disease (COVID-19). METHODS: Complete blood count (CBC) and PB cell morphology were examined in 38 healthy controls (HCs) and 40 patients with COVID-19. Patients with COVID-19, including 26 mild and 14 severe cases, were hospitalized in Juntendo University Hospital (Tokyo, Japan) between April 1 and August 6, 2020. PB examinations were performed using Sysmex XN-3000 automated hematology analyzer and Sysmex DI-60 employing the convolutional neural network-based automatic image-recognition system. RESULTS: Compared with mild cases, severe cases showed a significantly higher incidence of anemia, lymphopenia, and leukocytosis (P < .001). Granular lymphocyte counts were normal or higher in mild cases and persistently decreased in fatal cases. Temporary increase in granular lymphocytes was associated with survival of patients with severe infection. Red cell distribution width was significantly higher in severe cases than in mild cases (P < .001). Neutrophil dysplasia was consistently observed in COVID-19 cases, but not in HCs. Levels of giant neutrophils and toxic granulation/Döhle bodies were increased in severe cases. CONCLUSION: Basic PB examination can be useful to predict the prognosis of COVID-19, by detecting SARS-CoV-2 infection-induced multi-lineage changes in blood cell counts and morphological anomalies. These changes were dynamically correlated with disease severity and may be associated with disruption of hematopoiesis and the immunological system due to bone marrow stress in severe infection.


Subject(s)
Blood Cell Count , COVID-19/blood , Leukocytosis/etiology , Lymphocytes/ultrastructure , Lymphopenia/etiology , Neutrophils/ultrastructure , SARS-CoV-2 , Aged , Anemia/blood , Anemia/etiology , Blood Cell Count/instrumentation , Blood Cell Count/methods , COVID-19/mortality , Cell Shape , Cytoplasmic Granules/ultrastructure , Erythrocyte Indices , Female , Humans , Image Processing, Computer-Assisted , Leukocytosis/blood , Lymphocyte Count , Lymphopenia/blood , Male , Middle Aged , Neural Networks, Computer , Prognosis , Severity of Illness Index
11.
J Virol Methods ; 294: 114183, 2021 08.
Article in English | MEDLINE | ID: covidwho-1225322

ABSTRACT

BACKGROUND: The novel severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is responsible for the worldwide coronavirus disease-19 (COVID-19) pandemic, starting in late 2019. The standard diagnostic methods to detect SARS-CoV-2 are PCR-based genetic assays. Antigen-antibody-based immunochromatographic assays are alternative methods of detecting this virus. Rapid diagnosis kits to detect SARS-CoV-2 are urgently needed. STUDY DESIGN: Three monoclonal antibodies against SARS-CoV-2 nucleocapsid (N) protein were used to develop an antigen-antibody-based immunochromatographic kit to detect SARS-CoV-2. These assays were evaluated using  nasopharyngeal swab specimens collected from patients suspected of having COVID-19. RESULTS: These assays detected recombinant SARS-CoV-2 N protein at concentrations >0.2 ng/mL within 10 min after protein loading, but did not detect the N proteins of Middle East respiratory syndrome coronavirus (MERS-CoV), human coronaviruses OC43 (HCoV-OC43) and 299E (HCoV-229E) and other pathogens causing respiratory infections. Nasopharyngeal swab specimens obtained 1~3, 4~9, and ≥ 10 days after symptom onset from COVID-19 patients diagnosed by RT-PCR showed positivity rates of 100 %, >80 %, and <30 %, respectively. CONCLUSIONS: Kits using this immunochromatographic assay may be a rapid and useful tool for point-of-care diagnosis of COVID-19 when samples are obtained from patients 1~9 days after symptom onset.


Subject(s)
COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/immunology , Immunoassay/methods , Animals , Antibodies, Monoclonal/immunology , COVID-19/blood , Humans , Nasopharynx/virology , Phosphoproteins/immunology , Rats , SARS-CoV-2
12.
Sci Rep ; 11(1): 8380, 2021 04 16.
Article in English | MEDLINE | ID: covidwho-1189287

ABSTRACT

Healthcare workers (HCWs) are highly exposed to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. The actual coronavirus disease (COVID-19) situation, especially in regions that are less affected, has not yet been determined. This study aimed to assess the seroprevalence of SARS-CoV-2 in HCWs working in a frontline hospital in Tokyo, Japan. In this cross-sectional observational study, screening was performed on consented HCWs, including medical, nursing, and other workers, as part of a mandatory health checkup. The screening test results and clinical characteristics of the participants were recorded. The antibody seroprevalence rate among the 4147 participants screened between July 6 and August 21, 2020, was 0.34% (14/4147). There was no significant difference in the seroprevalence rate between frontline HCWs with a high exposure risk and HCWs working in other settings with a low exposure risk. Of those seropositive for SARS-CoV-2, 64% (9/14) were not aware of any symptoms and had not previously been diagnosed with COVID-19. In conclusion, this study provides insights into the extent of infection and immune status in HCWs in Japan, which has a relatively low prevalence of COVID-19. Our findings aid in formulating public health policies to control virus spread in regions with low-intensity COVID-19.


Subject(s)
COVID-19/diagnosis , Adult , Aged , Antibodies, Viral/blood , COVID-19/epidemiology , COVID-19/virology , Cross-Sectional Studies , Female , Health Personnel , Hospitals , Humans , Male , Middle Aged , SARS-CoV-2/isolation & purification , Tokyo/epidemiology , Young Adult
13.
PLoS One ; 16(2): e0246536, 2021.
Article in English | MEDLINE | ID: covidwho-1069627

ABSTRACT

We examined the usefulness of five COVID-19 antibody detection tests using 114 serum samples at various time points from 34 Japanese COVID-19 patients. We examined Elecsys Anti-SARS-CoV-2 from Roche, and four immunochromatography tests from Hangzhou Laihe Biotech, Artron Laboratories, Chil, and Nadal. In the first week after onset, Elecsys had 40% positivity in Group S (severe cases) but was negative in Group M (mild-moderate cases). The immunochromatography kits showed 40-60% and 0-8% positivity in Groups S and M, respectively. In the second week, Elecsys showed 75% and 50% positivity, and the immunochromatography tests showed 5-80% and 50-75% positivity in Groups S and M, respectively. After the third week, Elecsys showed 100% positivity in both groups. The immunochromatography kits showed 100% positivity in Group S. In Group M, positivity decreased to 50% for Chil and 75-89% for Artron and Lyher. Elecsys and immunochromatography kits had 91-100% specificity. Elecsys had comparable chronological change of cut-off index values in the two groups from the second week to the sixth week. The current SARS-CoV-2 antibody detection tests do not provide meaningful interpretation of severity and infection status. Its use might be limited to short-term epidemiological studies.


Subject(s)
Antibodies, Viral/immunology , COVID-19 Serological Testing/methods , COVID-19/diagnosis , COVID-19/immunology , Adult , Aged , COVID-19/virology , Female , Humans , Male , Middle Aged , Reagent Kits, Diagnostic , SARS-CoV-2/physiology , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL